Tektronix Webcam 070-8030-01 User Manual

Page of 652
Adjustment Procedures
1780R-Series Service Manual
5–5
Table 5–1: Recommended Equipment (Cont.)
Electrical Instrument
Example
Performance Requirements
5. Leveled Sine Wave Generator
Flatness 1%, 250 kHz to 50 MHz. The
flatness can be characterized (a chart
made of variations) with the TEKTRONIX
Peak-to-Peak Detector (015-0408-00).
TEKTRONIX SG503 Leveled Sine Wave
Generator installed in a TEKTRONIX
TM500 Series Power Module.
When using the TEKTRONIX SG503 the
following additional accessories are
needed:
Two 50 
W coaxial cables, Tektronix Part
No. 012-0482-00.
A 50-to-75 
W minimum loss attenuator,
Tektronix Part No. 011-0057-00.
6. Digital (Frequency) Counter
Range: 10 kHz to 20 MHz; accuracy,
±
0.001%.
TEKTRONIX DC 503A used in a TM500
Series Power Module.
7. Peak-to-Peak Detector Amplifier
Tektronix Part No. 015-0408-00 (includes
one 015-0413-00 Peak-to-Peak Detector
Head). Installed in a TEKTRONIX TM500
Series Power Module.
8. Detector Head
Two each, Tektronix Part No.
015-0413-00 for use with TEKTRONIX
Peak-to-Peak Detector Amplifier (item 7).
One Detector Head is supplied with the
Peak-to-Peak Detector.
9. Video Amplitude Calibration Fixture (VAC)
Signal; adjustable square wave 0.0 to
999.9 mV p-p with a resolution of 0.1 mV
and an accuracy of 0.05%, frequency
approximately 270 Hz.
TEKTRONIX 067-0916-00 used in a
TEKTRONIX TM500 Series Power
Module.
10. Sine Wave Oscillator
Signal: 10 Hz to 100 kHz sine waves; +
and – (minus) balanced outputs.
A TEKTRONIX SG505 Option 02
Oscillator installed in a TEKTRONIX
TM500 Series Power Module.
11. Function Generator
Signal: 1 kHz, +10 V, square waves for
adjusting YRGB compensation.
TEKTRONIX FG501A Function Genera-
tor installed in a TEKTRONIX TM500
Series Power Module.
12. Power Module Mainframe 
(required for Items 4, 5, 6, 7, 9, 10, and 11)
For powering and housing TEKTRONIX
DC503A, DM501A, FG501A, SG503,
SG505, 067-0916-00, and 015-0408-00.
For example: TEKTRONIX TM506 Power
Module Mainframe.
13. Variable Autotransformer
General Radio Metered Autotransformer
W10MT3W. If 220 V operation must be
checked, a conversion transformer or
appropriate 220 V autotransformer is
needed.