Tektronix Ventilation Hood AWG710 User Manual

Page of 580
FG Mode
3-234
AWG710&AWG710B Arbitrary Waveform Generator User Manual
Change the generator mode
AWG mode to FG mode
The instrument initializes in the AWG mode when powered on.
Do the following to change the generator mode from AWG to FG:
1. Push SETUP (front–panel)!Extended Operation (bottom)!
Ez FG... (side) button.
The instrument displays the FG mode screen. 
FG mode to AWG mode
Do the following to change the generator mode from FG to AWG:
1. Push Exit Ez FG... (bottom) button.
The instrument returns to the AWG mode.
Figure 3-77: Change the generator mode  (except option 02)
To F G
mode
FG mode screen
AWG SETUP screen
To AWG
mode
NOTE. 
All the parameters on the FG mode menu are independent of the AWG mode 
parameters. Therefore, the output parameters, such as frequency, amplitude and 
offset, have no effect on the parameters set with the SETUP menu while in the other 
mode.
In FG mode, the AWG710&AWG710B runs CONTINUOUS mode only.