Osburn Stoves by SB I HYBRID 35 User Manual
90 DEGREE ELBOW
45 DEGREE ELBOW
TERMINATION
COLLAR
COLLAR
WALL
STRAP
STRAP
FOLLOW CHIMNEY OR
VENT MANUFACTURER'S
INSTRUCTIONS
VENT MANUFACTURER'S
INSTRUCTIONS
WALL
THIMBLE
CLEAN OUT
TEE
TEE
Figure 15
Venting through wall
WALL
STRAP
STRAP
CLEAN OUT
TEE
TEE
VERTICAL ROOF VENT
1' HORIZONTAL RUN EVL = 1'
FOLLOW CHIMNEY OR
VENT MANUFACTURER'S
INSTRUCTIONS
VENT MANUFACTURER'S
INSTRUCTIONS
1' HORIZONTAL RUN EVL = 1'
90° ELBOW "T" LEE = 5'
VERTICAL LENGTH 4' EVL = 4 X 0.5' = 2'
VERTICAL LENGTH 4' EVL = 4 X 0.5' = 2'
VERTICAL LENGTH4' EVL = 4 X 0.5' = 2'
COUPE-FEU
MURAL
Figure 16
Venting trough wall
EQUIVALENT VENT LENGHT (EVL)
The longer the run of pipe in your installation, the more restriction there is
in the system. Therefore, larger diameter pipe should be used for longer
runs.
in the system. Therefore, larger diameter pipe should be used for longer
runs.
•
Use 4” pipe if you have more than 15 feet of Equivalent Vent Length
(EVL).
(EVL).
•
Horizontal runs shall not exceed 10 feet of EVL.
•
To calculate EVL, use the following conversions table:
Qty
Type of pipe
EVL equivalent(ft)
1
90° elbow or “T”
5
1 45°
elbow
3
1 ft
Horizontal pipe run
1
1 ft
Vertical pipe run
0.5
NOTE: At altitudes above 3,000 feet, we suggest the use of 4” diameter
vent at an EVL of 7 feet or more.
vent at an EVL of 7 feet or more.
Here is an example on how to calculate the EVL of your installation. (See
Figure 16)
Figure 16)
(3 x 4’ of vertical length = 12’ x 0.5 = 6 EVL) + (1 x elbow or "T" = 5 EVL) +
(2 x 1’ of horizontal length = 2 EVL)
(2 x 1’ of horizontal length = 2 EVL)
Total EVL = (6 + 5 +2) = 13. So 3” diameter vent is allowed
INSTALLATION CONFIGURATIONS
HORIZONTALLY THROUGH WALL
(refer to Figure 7 & 8)
NOTE: Follow L-Vent chimney manufacturer’s instructions.
1.
(refer to Figure 7 & 8)
NOTE: Follow L-Vent chimney manufacturer’s instructions.
1.
Position stove, adhering to clearances shown in Figures 1 & 2.
2. Determine position of hole in wall; directly behind stove exhaust vent
(refer to figure 4).
3.
Always maintain 3” clearance from combustible materials.
4.
Install L-Vent wall thimble per L-Vent manufacturer’s instructions.
5. Attach enough piping to go through and extend at least 6” beyond
exterior wall. An 8-foot vertical pipe run is suggested where possible
to reduce the possibility of smoke spillage caused by negative
pressure.
to reduce the possibility of smoke spillage caused by negative
pressure.
6. Attach cap and seal outside wall thimbles with non-hardening
waterproof mastic.
Termination should not be located so that hot exhaust gases can ignite
trees, shrubs, or grasses or be a hazard to children. Exhaust gases can
reach temperatures of 500ºF and cause serious burns if touched.
Locate terminations: a) not less than 3 feet above any forced air
inlet located within 10 feet; b) not less than 4 feet below or
horizontally from, or one foot above, any door, window or gravity
air inlet into any building; c) not less than two feet from an
adjacent building and not less than 7 feet above grade when
located adjacent to a public walkway. Mobile home installations
must use a spark arrester.