Technical information
Technical information
Output data at +7/35º and +7/45º are stated according to the European standard EN 14511.
1) 
Dimensions excl. feet, supplied min 20 mm - max 30 mm depending on adjustment.
Sound levels
The table describes the sound levels stated in sound pressure 
level.
Sound pressure level:
Sound pressure level is defi ned as the sound level, which at an ear 
level of 1.8 metres, is perceived one metre from the heat pump. 
Measured in a sound measurement room without echo at an 
outdoor temperature of +7ºC and 50ºC fl ow temperature.
Example:
When the heat pump is installed outside with free sound propaga-
tion the sound level drops by 6dBa with each doubling of distance.
Example
Optima 900
Optima 1400
Distance
Lp - ear (dBa)
Lp - ear (dBa)
1 metres
53
59
2 metres
47
53
4 metres
41
47
8 metres
35
41
Heat pump
Sound 
pressure level
Lp - ear (dBa)
Optima 600
53
Optima 900
53
Optima 1100
53
Optima 1400
59
Optima 1700
59
Model IVT Optima
600
900
1100
1400
1700
Emitted/Supplied output at +7/35º
kW
5,5 / 1,4
7,2 / 2,0
8,9 / 2,3
12,9 / 3,3
14,3 / 3,9
Emitted/Supplied output at +7/45º
kW
5,1 / 1,7
7,0 / 2,4
8,6 / 2,8
12,5 / 4,0
14,1 / 4,7
Heat carrier fl ow nominal
l/s
0,19
0,29
0,34
0,47
0,55
Internal pressure drop heat carrier
kPa
5
6
7
7
8
Air fl ow
m³/h
2200
2200
2200
5500
5500
Electrical consumption fan
A
0,44
0,44
0,44
0,7A (400V N3)
0,7A (400V N3)
Electrical supply
400V 3N~ 50Hz
Fuse size
AT
10
16
Compressor
Scroll
Highest outgoing heat carrier 
temperature
ºC
65
Refrigerant fi lling R-407C
kg
2,5
2,6
2,7
3,4
3,5
HTF connection, clamping ring
mm
Hose 1 inch internal thread
external 1 inch
Defrost system
Hot gas with four-way valve
Dimensions (WxDxH) 
1)
mm
820x640x1190
920x705x1660
Weight
kg
140
145
155
160
165
Colour
Champagne
Outer casing
Galvanised enamelled plate