Oregon Scientific PROFESSIONAL WEATHER CENTER WMR200 User Manual

Page of 11
10
EN
To view remaining days for records:
Press clock area 
 until DATA LOGGER mode is displayed.
 NOTE  When DATA LOGGER is full, i.e., no more records can be stored on unit, 
DATA LOGGER’ and ‘O Days’ will flash.  
To upload records to PC:
Plug USB and upload onto computer.
 NOTE  PC program provided must be installed before uploading of records from 
main unit.
To clear records:
1.  Press clock area 
 until DATA LOGGER is displayed.
2.  Press and hold MEM.
3.  All LED icons will light up and turn off consecutively (right to left).  Delete process 
is complete and successful
 
after blinking of last icon 
 .
RESET
Press RESET to return to the default settings.
TROUBLE SHOOTING
PROBLEM
SYMPTOM
REMEDY
Barometer
Strange readings
Set unit
Calendar
Strange date / month
Change language
Clock
Cannot adjust clock
Disable radio-controlled clock
Cannot auto-synch
1. 
Adjust batteries
2. 
Press RESET
3. 
Manually activate radio 
         controlled clock
Temp
Shows “LL” or “HH”
Temperature is out-of-range
Remote 
sensor
Cannot locate 
remote sensor
1. 
Check batteries
2. 
Check if sensors are 
         within range
PRECAUTIONS
•  Do not subject the unit to excessive force, shock, dust, temperature or humidity.
•  Do not cover the ventilation holes with any items such s newspapers, curtains 
etc.
•  Do not immerse the unit in water. If you spill liquid over it, dry it immediately with 
a soft, lint-free cloth.
•  Do not clean the unit with abrasive or corrosive materials. 
•  Do  not  tamper  with  the  unit  ’s  internal  components.  This  invalidates  the 
warranty.
•  Only use fresh batteries. Do not mix new and old batteries.
•  Images shown in this manual may differ from the actual display.
•  When  disposing  of  this  product,  ensure  it  is  collected  separately  for  special 
treatment.
•  Placement of this product on certain types of wood may result in damage to its 
finish  for  which  Oregon  Scientific  will  not  be  responsible.  Consult  the  furniture 
manufacturer's care instructions for information.
•  The contents of this manual may not be reproduced without the permission of the 
manufacturer.
•  Do  not  dispose  old  batteries  as  unsorted  municipal  waste.    Collection  of  such 
waste separately for special treatment is necessary.
•  Please note that some units are equipped with a battery safety strip. Remove the 
strip from the battery compartment before first use.
  NOTE   The  technical  specifications  for  this  product  and  the  contents  of  the  user 
manual are subject to change without notice.
SPECIFICATIONS
MAIN UNIT
Dimensions 
149 x 198 x 47 mm
(L x W x H) 
(5.9 x 7.8 x 1.9 inches)
Weight 
510 g (1.12 lbs) without battery
INDOOR BAROMETER
Barometer unit 
mb/hPa, inHg and mmHg
Measuring range 
700 – 1050mb/hPa
Accuracy  
+/- 10 mb/hPa
Resolution 
1mb (0.0 inHg)
Altitude setting 
Sea level
 
User setting for compensation
Weather display  
Sunny, Clear night, Partly Cloudy, Cloudy,
 
Cloudy at night, Rainy and Snowy 
Memory 
Historical data and bar chart for last 24hrs
INDOOR TEMPERATURE
Temp. unit 
°C / °F
Displayed range 
0°C to 50°C (32°F to 122°F)
Operating range 
-30°C to 60°C (-4°F to 140°F)
Accuracy 
0°C - 40°C: +/- 1°C (+/- 2.0°F)
 
40°C - 50°C: +/- 2°C (+/- 4.0°F)
Comfort 
20°C to 25°C (68°F to 77°F)
Memory 
Current, Min and Max temp.
 
Dew Point w/ Min and Max
Alarm 
Hi / Lo
INDOOR RELATIVE HUMIDITY
Displayed range 
2% to 98%
Operating range 
25% to 90%
Resolution 
1%
Accuracy 
25% - 40%: +/- 7%
 
40% - 80%: +/- 5%
 
80% - 90%: +/- 7%
Comfort 
40% to 70%
Memory 
Current, Min and Max
Alarm 
Hi / Lo
RADIO-CONTROLLED / ATOMIC CLOCK
Synchronization 
Auto or disabled
Clock display 
HH:MM:SS
Hour format 
12hr AM/PM or 24hr
Calendar 
DD/MM or MM/DD
Weekday in 5 languages 
(E, G, F, I, S)
Battery  
4 x UM-3 (AA) 1.5V batteries
 
AC adapter 6V
REMOTE WIND SENSOR UNIT
Dimensions (L x W x H) 
178 x 76 x 214 mm (7 x 3 x 8.4 inches)
Weight 
100 g (0.22 lbs) without battery
Wind speed unit 
m/s, kph, mph, knots
Speed accuracy 
2 m/s ~ 10 m/s (+/- 3 m/s)
 
10 m/s ~ 56 m/s (+/- 10%)
Direction accuracy 
16 positions
Transmission of  
Approx. every 14 seconds
wind speed signal 
Memory 
Max speed gust
Battery  
2 x UM-3 (AA) 1.5V batteries
OUTDOOR TEMPERATURE / HUMIDITY UNIT
•   RELATIVE TEMPERATURE
Dimensions 
115 x 87 x 118 mm
(L x W x H) 
(4.5 x 3.4 x 4.6 inches)
Weight 
130 g (0.286 lbs) without battery
Temp. unit  
°C / °F
Displayed range 
-50°C to 70°C (-58°F to 158°F)
Operating range 
-30°C to 60°C (-4°F to 140°F)
Accuracy 
-20°C – 0°C: +/- 2°C (+/- 4.0°F)
 
0°C - 40°C: +/- 1°C (+/- 2.0°F)
 
40°C - 50°C: +/- 2°C (+/- 4.0°F)
 
50°C - 60°C: +/- 3°C (+/- 6.0°F)
Comfort 
20°C to 25°C (68°F to 77°F)
Memory 
Current, Min and Max temp.
 
Dew Point w/ Max and Min
 
Wind chill temp. and min
•   RELATIVE HUMIDITY
Displayed range 
2% to 98%
Operating range 
25% to 90%
Resolution 
1%