Oracle Vacuum Cleaner CPU-56T User Manual

Page of 145
Introduction
OpenBoot Firmware
SPARC/CPU−56T
95
When OBDIAG is called, the <obdiag> test prompt appears and you can now choose the
required test. You can run single tests, a number of tests, all tests, or all tests with
exceptions. If the test has passed successfully, a short test comment will appear on screen.
In order to return to the main menu, hit the enter key.
Terminating OBDIAG
In order to terminate OBDIAG and return to OpenBoot, enter
a
exit
The OpenBoot prompt will then reappear.
a
OBDIAG Commands
Apart from testing the hardware, you can also call several commands which can be seen
in the ODBIAG main menu. The following table provides an overview of these
commands.
a
Table 16:
 OBDIAG Commands
Command
a
Description
a
exit
Exits obdiag tool
help
Prints this help information
setenv
Sets diagnostic configuration variable to new value
printenvs
Prints values for diagnostic configuration variables
versions
Prints selftests, library, and obdiag tool versions
test−all
Tests all devices displayed in the main menu
test 1,2,5
Tests devices 1, 2, and 5
except 2,5
Tests all devices except for devices 2 and 5
what 1,2,5
Prints some selected properties for devices 1, 2, and 5
OBDIAG provides a brief excerpt of the OpenBoot configuration variables. The values of
the variables are displayed after entering the following command:
printenvs
You can decide whether the chosen test will either stop at the occurrence of the first error
or continue to test the hardware. It is also possible to run the test more than once or
produce a detailed print−out of the test.
The example below shows the detailed print out of an OBDIAG test.
a
Example:
a