III.  General Specifications & Fan Performance Curves
Physical and Electrical Data for 3 hp High Vacuum Unit.
3hp  - 1342 cfm @ 3.5 SP
System Performance
Height w/ 55 Gal. Drum: 110 1/8”
Footprint: 56” x 34”
Fan Wheel diameter: 15” Backward Incline design
Cyclone Inlet: 6”
System Dimensions
TEFC 60 Hz Motor - Single Phase
Insulation Class: F4
Voltage: 230
Amperage: 14.5
Made in U.S.A.
Integral Fan Blower - 3hp
1 Pleated Cartridge - 130 sq. ft.
Spun-Bonded polyester BIA ZH1 / 487 test - Rated C
Captures 99.99% of test material over 20 microns
Captures 99.9% of test material between 0.2 - 2.0 microns @ 11fpm
External Cartridge Filter
55 Gal. Steel Drums
Large dust bins available
Dust Bin
Magnetic Motor Starter
Filter Efficiency Gauge
Included:
Static pressure and volume together determine a fan’s performance. Several factors, such as layout of
ductwork and diameter of openings, can affect a fan’s performance.
13
11
9
7
5
3
0
0
200
400
600
800
1000
1200
1400
1600
CFM
S
tatic Pressure at Cyclone Inlet
System Performance Curve
12.5
10.9
9.1
6.8
3.5
1342
1045
842
618
0
3.5
6.8
9.1
10.9
12.5
CFM
Static @
Cyclone Inlet