Omega OMG-USB-SER-2 User Manual

Page of 21
 
Configuration 
OMG-USB-SER-2 
Page 7 
 
Switch Examples Continued 
 
 
 
Port 2 
 
 
 
    Port 1 
 
 
Figure 3: Electrical Interface Configuration 
 
Port 1 :  RS-232 
The  corresponding shunt is in the 232 position. The switches will have 
no effect. 
 
Port 2 :   RS-485 two wire communication with no echo. 
 
The corresponding shunt is in the 422/485 position.  Switches 485 2,  
NE 2, and  Port 2 L, L, T, PU, and PD are all in the ON position.   
 
RS 232
RS 232
RS 422/485
RS 422/485
ON
1
2
3
4
5
6
7
8
OFF
9
10
Port 1
    L
    L
    T
    PU
    PD
Port 2
    L
    L
    T
    PU
    PD
E5
E6
E7
E8
SW4