Chapter 7  Managing Libraries
Changing the Library State
StorNext User’s Guide
181
Changing the Library State
This function allows you to change a library’s logical state to online or 
offline. Logical state means the library could be online, but StorNext treats 
it as offline. 
To physically take a SCSI library offline, use the library’s front panel. To 
take a network library physically offline, use the library's controller 
software.
1
From the SNSM home page, choose Library > Library State from the 
Admin menu. The Change Library State screen appears.
Figure 127  Change Library 
State Screen
2
Select the library whose logical state you want to change. (The 
library’s current state is shown.)
3
Select the new state for the library you selected.
4
Click Apply to change the library’s state.
5
When the Status screen informs you that the library state was 
successfully changed, click OK.
6
If desired, repeat steps 2 - 5 to change the state for additional 
libraries.