Page 37
DGPS (cont’d) 
There’s no DGPS indicator on the Chart 
screen, and:
The BEACON RX SELF-TEST AND SOFT-
WARE message reads 
PASSED, AND 
THE DGPS STATUS 
message reads 
SEARCHING
.
Wait 30 minutes after start-up (only if 
a new unit) so the receiver can find a 
differential transmitter within range) 
check local knowledge or transmit-
ters). 
Check for high noise level, possibly 
due to a storm front, or for local inter-
ference at the marina or on the ves-
sel. See the Northstar 961 Operations 
and Reference Manual (GM1700)
 for 
details about noise-level meanings.
Turn off power to each and all of the 
vessel’s other instruments, one at a 
time, to isolate the source of the inter-
ference.
Try manually selecting and setting a 
DGPS beacon station to be used to 
see if the signal can be received. 
Consult the Coast Guard's Local 
Notice to Mariners to determine if 
there may be a scheduled mainte-
nance outage for the station you’re 
trying to use. 
For additional guidance, call the 
Northstar Service Department. 
DGPS (cont’d)
There’s no DGPS indicator on the CHART 
screen, and: 
The BEACON RX SELF-TEST AND SOFT-
WARE reads PASSED, and the DGPS 
STATUS message reads OLD CORREC-
TIONS
.
No DGPS corrections have been 
received, and the system has 
returned to non-differential operation. 
You may be out of range of a transmit-
ter, or if you’re experiencing bad 
weather, noise may be interfering. In 
either case, you must wait. 
DGPS (cont’d)
There’s no DGPS indicator on the CHART 
screen, and: 
The BEACON RX SELF-TEST AND SOFT-
WARE reads PASSED, and the DGPS 
STATUS
 
message reads POOR DOPS
.
Wait for the satellite configuration to 
automatically update, which should 
only take a few minutes.
DGPS (cont’d)
There’s no DGPS indicator on the CHART 
screen, and: 
BCN UNHEALTHY is displayed.
Wait—the transmitter is switching to 
another beacon. You can try manually 
switching to another transmitter. 
Table 2:  Troubleshooting the installation (continued) 