Event messages
Event message display
Cause
(U.S. only) Unable to activate all registered 
portables. The system ran out of portable 
credits. One event is generated per portable 
that failed to activate. The repetition of the 
corresponding alarm code 59 indicates how 
many additional credits must be purchased.
The base station (on port 0103 in this case) 
cannot successfully receive the data image.
Both radios belonging to the base station are 
disabled. This may occur if the flash EEPROM 
is faulty. Two events are raised: one for the B1 
channel radio (as in this case) and another for 
the B2 channel radio. A corresponding alarm 
code 53 occurs.
The base station (on port 0103 in this case) 
cannot be written to during data transfer.
Both radios belonging to the base station are 
disabled. The base station flash EEPROM is 
faulty. Two events are raised: one for the B1 
channel radio (as in this case) and another for 
the B2 channel radio. A corresponding alarm 
code 53 occurs. 
The base station (on port 0103 in this case) 
cannot be synchronized with the other base 
stations in the system.
Both radios belonging to the base station are 
disabled. The base station hardware is faulty. 
Two events are raised: one for the B1 channel 
radio (as in this case) and another for the B2 
channel radio. A corresponding alarm code 53 
occurs.
A B2 channel radio (radio 2 on port 0103 in this 
case) cannot be synchronized with other radios 
because of system overload.
Evt:275-3546 
S8
Evt:301-1031
S5
Evt:302-1031
S5
Evt:303-1031
5
Evt:304-1032