RPI components 
The RPI-8, which has only one power supply unit, has 
grounding straps and plates fitted so it can be upgraded to an 
RPI-16 (see illustration RPI components).
Wiring the RPI
The maximum two-way DC loop resistance for power pairs, 
including interconnections for each base station, is 75 ohms. 
You need one or two power pairs between the RPI and the base 
station, depending on the wire size of the power pairs and the 
distance between the base station and the RPI.
Unplug the RPI power cord.
Do not apply power to the RPI until its installation and 
wiring are complete. 
Do not run unprotected power cables outdoors.
PSU 1
PSU 2
(if equipped)
Up to 16 outputs
(TCM + power)
Up to 
16 
inputs
(TCM)
Connection board
Jumper lead to PSU 2
Power cord
Grounding strap 
Power supply cabling
Strain relief support
Clip
Grounding plates
Ferrite rings
Jumper lead to PSU2
PSU1
PSU2
(if equipped)
Grounding strap
Ferrite rings
Power supply cabling
Connection board
Up to 16 outputs
(TCM + power)
Up to 
16 
Inputs
(TCM)
Clip
Power cord
Strain relief system
Grounding plates