Nortel Networks CTA 500dm User Manual

Page of 86
AT commands   31
P0873832  Issue 05
 
 CTA 500
dm On Line Guide
Load Stored Profile
The Load Stored ProÞle Command 
Z[value]
or
&F[value]
instructs the CTA 500dm to load all values that are stored in a 
proÞle. Value 0 indicates that the factory proÞle should be loaded. 
Value 1 indicates that the user proÞle should be loaded.
Any calls in progress are disconnected when you use this command.
The Z command selects the user proÞle (default value 1).The &F 
command selects the factory proÞle (default value 0). Using either 
command, if no value is speciÞed, the default proÞle is used.
Result Codes
OK  Appears when the command is executed.
ERROR  Appears when the command could not be executed.
Load Stored Profile on Start-up
The Load Stored ProÞle on Start-up Command
&Y[value]
instructs the CTA 500dm to load all values that are stored in a proÞle 
after a power-up or after a DTR reset if &D is set to 3 (see
Value 0 indicates that the factory proÞle should be loaded at start-up. 
Value 1 indicates that the user proÞle should be loaded at start-up. If 
no value is speciÞed, the default factory proÞle is used.
Result Codes
OK  Appears when the value is recognized or not supplied.
ERROR  Appears when the value is invalid or unrecognized.