42   AT commands
 CTA 500
dm On Line Guide
 
P0873832  Issue 05
Set S-Register
The Set S-Register Command 
Sregister number=[value]
instructs the CTA 500dm to set the speciÞed S-register to a value. 
The register number must be speciÞed. An unspeciÞed value causes 
the register to have a default setting and an initial factory value.
Result Codes
OK  Appears when the command is successfully completed.
ERROR  Appears when the chosen register or the value for the 
register is invalid.
Query S-Register
The Query S-Register Command 
Sregister number?
instructs the CTA 500dm to return the value of the selected S-
register.
Result Codes
OK  Appears on a new line following display of the S-register value.