 NT1R20 Off-Premise Station Analog Line card
Configuring the OPS analog line card
The line type, terminating impedance, and balance network configuration for 
each unit on the card is selected by software service change entries at the 
system terminal and by jumper strap settings on the card. 
Jumper strap settings
Each line interface unit on the card is equipped with two jumper blocks that 
are used to select the proper loop current depending upon loop length. See 
Table 71. 
For units connected to loops of 460 to 2300 ohms, both jumper blocks for that 
unit must have jumper blocks installed. For loops that are 460 ohms or less, 
jumper blocks are not installed. Figure 24 on 
 shows the location of 
the jumper blocks on the OPS analog line card.
Table 71
OPS analog line card – configuration (Part 1 of 2)
Application
On-premise station (ONS)
Off-premise station (OPS)
Class of Service 
(CLS) (Note 1)
ONP
OPX
Loop resistance 
(ohms)
0–460
0–2300 (Note 2)
Jumper strap 
setting (Note 6)
Both JX.0 and JX.1 
off
Both JX.0 and JX.1 
off
Both JX.0 and JX.1 
on
Loop loss (dB) 
(Note 3)
0–1.5 
>0–3.0 
>2.5–3.0 
0–1.5 
>1.5–2.5 
>2.5–4.5 
>4.5–15
TIMP 
(Notes 1, 4)
600 
ohms
600 
ohms
600 
ohms
600 
ohms
600 
ohms
600 
ohms
600 
ohms
BIMP 
(Notes 1, 4)
600 
ohms
3COM
3CM2
600 
ohms
3COM
3CM2
3CM2