A maximum of eight MSDL cards can be installed in a fully occupied 
module because of the module’s power supply limitations.
The Clock Controller card should not be installed in a module if more 
than 10 MSDL ports are configured as active RS-232 (rather than 
RS-422) ports in that module because of the module’s power supply 
limitations.
The MSDL address must not overlap other card addresses.
Before downloading a peripheral software module for an MSDL, disable 
all MSDL ports on cards running the same type of operation.
Environmental and power requirements
The MSDL card conforms to the same requirements as other interface cards. 
The temperature, humidity, and altitude for system equipment, including the 
MSDL, should not exceed the specifications shown in Table 152.
A stable ambient operating temperature of approximately 22°C (72°F) is 
recommended. The temperature differential in the room should not exceed 
±3°C (±5°F).
Table 152
Environmental requirements
Condition
Environmental specifications
Operating
Temperature
Relative Humidity
Altitude
0° to 50° C (32° to 122° F)
5% to 95% non-condensing
3,048 meters (10,000 feet) maximum
Storage
Temperature
Relative Humidity
–50° to 70° C (–58° to 158° F)
5% to 95% non-condensing