 NT8D14 Universal Trunk card
Jumper strap settings
For most applications, the jumper strap settings remain set to the standard 
configuration as shipped from the factory. See Table 190 on 
The jumper strap settings must be changed, as shown in Table 191 on 
, for the following:
For CO/FX/WATS or TIE trunk loops exceeding 1524 meters (5000 ft.)
Table 192
Trunk types – termination impedance and balance network (NT8D14BA, NT8D14BB)
Trunk types
Terminating 
impedance 
(Note 1)
Balance network for loop lengths (Note 2)
0–915 m
 (0–3000 ft)
915–1524 m
(3000–5000 ft)
> 1524 m 
(> 5000 ft)
CO/FX/WATS
600 or 900 
ohms
600 ohms
3COM
3CM2
2-way TIE (LDR)
600 or 900 
ohms
600 ohms
3COM
3CM2
2-way TIE (OAID)
600 or 900 
ohms
600 ohms
3COM
3CM2
DID (loop length 
< 600 ohms)
600 or 900 
ohms
600 ohms
3COM
3CM2
DID (loop length 
Š 600 ohms)
600 or 900 
ohms
600 ohms
N/A
3CM2
RAN: continuous 
operation mode
600 or 900 
ohms
600 or 900 ohms
N/A
N/A
Paging
600 ohms
600 ohms
N/A
N/A
Note 1: The terminating impedance of each trunk unit is software selectable in LD 14 and 
should match the nominal impedance of the connecting equipment.
Note 2: The balance network of each trunk unit is software selectable between resistive 600 or 
900 ohms or 3COM and jumper selectable between 3COM and 3CM2. Jumper selection for 
3COM/3CM2 restriction does not apply to NT8D14BB.