Nortel Networks Circuit Card User Manual

Page of 908
 NTAK79 2.0 Mb PRI card
 Page 751 of 906
Switch SW4 – Carrier Shield Grounding
This switch enables for the selective grounding of the Tx / Rx pairs of the 
carrier cable. Closing the switch (down position) applies Frame Ground 
(FGND) to the coaxial carrier cable shield, creating a 75 ohms unbalanced 
configuration. This applies only to the NTBK05CA cable. 
Note: The usual method is to ground the outer conductor of the receive 
coaxial signal.
Power requirements
The NTAK79 obtains its power from the backplane, drawing maximums of 
2 A on +5 V, 50 mA on +12 V and 50 mA on –12 V.
Environment
The NTAK79 meets all applicable Nortel Network’s operating specifications.
Functional description
The NTAK79 card provides the following features and functions:
recovery of the 2.048 kbps data by the CEPT receiver, at signal levels 
which have been attenuated by up 10 dB
control of CEPT line density using HDB3 which provides 64 kbps clear 
channel
performance monitoring of the receive carrier by means of Bipolar 
Violations (BPV), Slips, CRC-4 (CRC), and Frame Bit Errors (FBER)
Table 243
Switch SW4
Switch
Down (On)
Up (Off)
SW 4-1
Rx – FGND
Rx – OPEN
SW 4-2
Tx – FGND
Tx – OPEN