Nortel Networks Circuit Card User Manual

Page of 908
 NTCK16 Generic Central Office Trunk cards
 Page 797 of 906
Pad switching
The NTCK16AX and NTCK16BX generic Central Office trunk cards 
support the North American loss plan. Software configuration allows the 
selection of 4 dB loss pads on a per unit basis.
Note: The tolerance for the above nominal values is +0.3 dB, -0.7 dB.
Connector pin assignments
Cross connections
 provide cross connect information for the NTCK16AX and 
NTCK16BX generic Central Office trunk cards.    
Configuration
The trunk type for each unit on the card is selected by software service change 
entries at the system terminal.
Storage temperature
–20 to +60 degrees C
Storage humidity
5 to 95% Relative Humidity
Table 258
NTCK16 pad switching
Loss
Analog-to-Digital
Digital-to-Analog
PAD out
0 dB
–3 dB
PAD in
+4 dB
+1 dB
Table 257
NTCK16 circuit card environmental specifications (Part 2 of 2)
Parameter
Specifications