Nortel Networks Circuit Card User Manual

Page of 908
 NTCK16 Generic Central Office Trunk cards
 Page 801 of 906
NTCK16AX Central Office trunk card
Route Data Block
Respond to the prompts in LD 16 as shown.
LD 16 – Route Data Block for NTCK16AX.
Prompt
Response
Description
REQ:
NEW
Define a new unit
TYPE:
COT
Define a new Route Data Block
CUST
xx
Customer number as defined in LD 15.
ROUT
Route number
0-511
Range for Large System, Call Server 1000E, 
and Media Gateway 1000E
0-127
Range for Small System, CS 1000S system, 
Media Gateway 1000B, and 
Media Gateway 1000T
TKTP
COT
Define trunk type as Central Office 
ICOG
IAO
Incoming and Outgoing trunk
CNTL
YES
Change a trunk timer
TIMER
RGV 256
Set Ring Validation Timer to 128 ms.
MR
(NO) PPM XLD