Controller Installation
Adept SmartController User’s Guide, Rev. E
33
Figure 2-8. 24V Connectors
NOTE: Although no damage will occur, the SmartController will not turn 
on if the DC polarities on the XDC connectors are reversed.
IEEE 1394 Cable Specifications
Adept supplies the IEEE 1394 cables to connect the SmartController to other Adept 
devices in the system. If you need a cable of a different length than those supplied by 
Adept, then you must purchase a cable from one of the Adept-approved vendors listed 
below:
• Newnex Technology Corp. Go to
• Molex, Inc. Go to
 
 
These purchased cables must meet all specifications of the IEEE 1394 standard. Note that 
Adept uses 6-pin to 6-pin cables. The maximum length for a 1394 cable is 4.5 meters. The 
1394 Trade Association provides detailed specifications for 1394 cables and other related 
information, see 
WARNING: 
You must use cables from vendors approved 
by Adept that meet all specifications of the IEEE 1394 
standard. Using a non-approved or inferior quality IEEE 
1394 cable can cause unpredictable system performance.
Insert small flat-blade screwdriver 
to open clamp.
Insert wire, then remove screwdriver 
to secure wire in clamp.
positive (+)
negative (-)
24VDC connector
Adept Part # 25040-00201