FIXATION AT CORNERS AND TEE CONNECTORS
Standard distance between pipe brackets is some 2 m.
MOUNTING OF PIPE LINES/GENERAL INSTRUCTIONS
-   Shorten the pipes by sawing off and take off burrs.
-   When bending the pipe bending radii should not be smaller than those stated in the chart 
under “U-bends/hose connections” and the bending should always be completed in a bend-
ing tool with rolling matrixes in order to prevent deformation of the pipe.
-   Union nut and cutting ring should be greased with oil and the cutting ring should be pre-fitted 
to the pipe in the screw joint or the annealed pre-mounting socket before fitting the pipe.
-   Place the pipe brackets at a maximum interval of 2 m.
-   Use ∅6 hexagon-headed screw with expansion joint for wall or concrete walls when 
  mounting wall fittings, alternatively use a knock-type anchor for concrete walls, e.g. HILTI 
type HPS 8/30.
-   In systems meant for hot water, care should be taken to place the pipe brackets on a straight 
line in order to prevent the lengthwise expansion of the pipe.