degradation of output noise. We recommend that the sources and loads you use have the same 
desirable characteristics. 
It is sometimes claimed that connecting cable shield at both ends creates ground loop, and that the 
current flowing in such loop will produce noise. This is not the case for most professional audio 
equipment. In short, there are two kinds of loop in which voltages are present: the loop formed by signal 
wires, and the looS12 formed by grounded conductors, among which are protective earth conductors 
(PE) and signal cable shields.  
When a cable shield is grounded at both ends, a loop is closed, and the resulting current causes a 
reduction of the voltage induced on signal lines. This effect is what the cable shield is intended to 
produce, since this is how it protects your signal from magnetic fields. 
If you are using an asymmetrical (unbalanced) source, it is recommended to use a shielded twisted pair 
and to connect wire 3 of the cable to the 
shield at the source output end (see figure). 
This technique prevents noise currents 
flowing on the return path of the signal. If 
you are using an amplifier with an 
asymmetrical (unbalanced) input, it is best to 
use a shielded twisted pair, and to connect 
wire 3 at the TDcontroller end only, as 
shown in Fig. 2. This keep a good 
capacitance balance for the signal, however 
noise currents flow on the return path of the 
signal. (Note that this is only acceptable for a 
short cable). 
If you are using a symmetrical (balanced) 
source or amplifier which is prone to become 
noisy when a current of less than 100 mA at 
the mains frequency (50 Hz or 60 Hz) is 
sourced into pin 1 of its XLR connectors, you might consider opening the ground loop. 
 
8.4  Analogue TDcontroller USER GUIDE 
 
Low Z
1
2
3
Low Z
1
2
3
TDcontroller
Amplifier
Mixing Desk
1
2
3
1
2
3
+
-
+
-
+
-
+
-
Low Z ?
L
o
w Z ?
?
PE
PE
Safety 
Ground
SHIELD
SHIELD
0V
IN
OUT