CAUTION: 
Hot while in operation.  Do Not Touch.  Keep children, clothing, furniture, 
gasoline, and other liquids having flammable vapors away. 
CAUTION:
 DO NOT TRY TO ADJUST HEATING LEVELS BY USING THE 
MANUAL SHUTOFF VALVE.
 
 
WARNING: 
  Improper installation, adjustment, alteration, service or maintenance can 
cause property damage, personal injury, or loss of life.  Refer to owner’s information manual 
provided with this appliance.  Installation and service must be performed by a qualified 
installer, service agency, or the gas supplier.
 
 
IMPORTANT:
  Always operate the appliance at the completely “ON” or the completely 
“OFF” positions.  Never use the heater at a setting between these positions as this can result in 
improper combustion and excessive carbon monoxide emissions. 
PILOT 
PILOT  BURNER 
IGNITER ELECTRODE 
THERMO-COUPLE 
O.D.S 
14. Close the access panel door. 
15. “Turn on all electric power to the appliance.” 
                                            CAUTION   
     DO NOT TRY TO ADJUST HEATING LEVELS BY USING THE  
     MANUAL SHUTOFF VALVE. 
 
    TO TURN OFF GAS TO APPLIANCE 
 
 
           SHUTTING OFF  UNIT: 
1.  Open access panel door, located in lower front center of base for access to control knobs.                      
2.  Set thermostat (flame control) to lowest setting.  
3.  Turn control knob clockwise                       to the full “OFF” position. 
4.  “Turn off all electrical power to the appliance if service is to be performed.” 
5.  Close access panel door. 
            SHUTTING OFF BURNER ONLY  (pilot stays lit)  
1.  Open access panel door, located in lower front center of base for access to control knobs.                      
2.  Turn control knob clockwise                       to the “PILOT” position. 
3.   Close access panel door.
  