NEC N 1093100 User Manual

Page of 984
Central Office Calls, Answering
DSX Software Manual
Features
◆ 75
Features
Programming
Basic Programming
1.
2.
In 3101-03: DTMF Dialing (page 811), indicate whether the line is DTMF (
1
) or Dial Pulse (
0
).
3.
In 3103-03: Loop Length (page 815) for analog lines only, set this option to compensate for the telco cir-
cuits loop length.
- For normal installations, enter 
0
.
- If the system is very close to the central office or behind a PBX, enter 
1
.
- If the loop length is abnormally long, enter 
2
.
1.
Review the following timers:
1.
For no incoming or outgoing access, in 2131-[01-64]: Line Access (page 763) enter 
0
.
2.
1
.
3.
2
.
4.
3
.
1.
For lamp only (no ringing) day and night, in 2132-[01-64]: Line Ringing (page 764) enter 
1
.
2.
For day and night ringing, in 2132-[01-64]: Line Ringing (page 764) enter 
2
.
3.
3
.
4.
For delay ringing day and night, in 2132-[01-64]: Line Ringing (page 764) enter 
4
.
In 1604-01: Delay Ring Timer (page 678), set the interval after which a delay ring line will change 
from flashing to ringing.
5.
For single line telephones:
Yes
.
- To have single line telephones follow the ringing pattern of the outside line, in 1403-02: Single 
No
.
1.
Make sure each line’s circuit type and loop length setting match the requirements of the 
connected service.
2.
Review the system timers for compatibility with the connected service.
3.
Set the line access options at extension for each line.
4.
Set the line ringing options at extension for each line.