NEC 2400 PX User Manual
NEAX2400 IPX Feature Programming Manual
Page 520
NDA-24297, Issue 1
M-44
Multiple Call Forwarding - All Calls
FCCS Programming
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
Note
STEP 1:
ASYDN
- These data must be set to the NCN.
System Data 1 Index 69, b7. Enable Multiple Call Forwarding-Busy Line/Don’t Answer/All Calls. 0/
1=Out of Service/In Service. Index 5, b1-b3. Assign the number of time for forwarding.
1=Out of Service/In Service. Index 5, b1-b3. Assign the number of time for forwarding.
Note:
When using ASYDL or ASYDN to program an FCCS feature, the basic programming of ASYD is required
in addition to ASYDL or ASYDN.
in addition to ASYDL or ASYDN.