NEC NEAX2000 IVS2 User Manual

Page of 475
CHAPTER 1  CUSTOMIZING OFFICE DATA
How to Customize Office Data
NEAX2000 IVS
2
 Office Data Programming Manual
 
 
ND-70931 (E), Issue 2.0
  
Page 7
• Type of Telephone
The type of station telephone set is specified as follows:
TYPE OF TEL  
       DESCRIPTION   
DP . . . . . . . . . . . . . 
Dial Pulse Telephone set
PB  . . . . . . . . . . . . . 
DTMF Telephone set
D
term
 . . . . . . . . . . . 
D
term
 set
• SERVICE CLASS-A/B/C
Specify the service class (1-15) programmed in the Service Restriction Data Table.
• RESTRICTION CLASS-DAY/NIGHT
Specify the Trunk Restriction Class as follows:
1: Unrestricted
2: Non-Restricted-1
3: Non-Restricted-2
4: Semi-Restricted 1
5:  Semi-Restricted 2
6:  Restricted 1
7:  Restricted 2
8:  Fully-Restricted
• DIT TRUNK NUMBER
In the case of the Direct-In Termination (DIT) station, specify the trunk number connected.
Trunk Data
In 
), the following data is required:
• ACCESS NUMBER
Specify the access code for the trunks.
• DESTINATION
Specify the distant office such as Central Office (Public Exchange), Tie Line, etc.