11.1.2.1  Device Long Response  
Echoing command: 
Start 
Address (optional) 
Body 
Delimiter 
device_id
Command SP [
Param1 ,Param2 …] result 
CR LF 
 
CR = Carriage return (ASCII 13 = 0x0D) 
LF = Line feed (ASCII 10 = 0x0A) 
SP = Space (ASCII 32 = 0x20) 
11.1.3 
Command Terms 
Command  
A sequence of ASCII letters ('A'-'Z', 'a'-'z' and '-'). 
Command and parameters must be separated by at least one space. 
Parameters 
A sequence of alphanumeric ASCII characters ('0'-'9','A'-'Z','a'-'z' and some special 
characters for specific commands). Parameters are separated by commas. 
Message string 
Every command entered as part of a message string begins with a message 
starting character and ends with a message closing character.  
Note: A string can contain more than one command. Commands are separated by 
a pipe ( '|' ) character. 
Message starting character 
'#' 
– For host command/query 
'~' 
– For device response 
Device ID (Optional, for K-NET) 
K-NET Device ID followed by '@' 
Query sign 
'?' follows some commands to define a query request. 
Message closing character 
CR  
– For host messages; carriage return (ASCII 13) 
CRLF 
– For device messages; carriage return (ASCII 13) + line-feed (ASCII 10)