Kenwood TV Mount TS-2000 User Manual

Page of 79
25
TS-2000/B2000/2000X
TS-2000S/2000V/2000SX/2000VX
ADJUSTMENT (K/E TYPE)
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
22. ALC meter 
start point
1) Menu No. : 87
  (Frequency : 14.1MHz)
 Transmit
Power 
meter
Rear
panel
ANT1
Front 
panel
[+] key 1 push
(ALC meter lights up to 1)
Zone max.
2) Menu No. : 88
 Transmit
(ALC meter zone max.)
23. FM DEV
 Wide
1) Menu No. : 89
  (Frequency : 29.1MHz)
 Transmit
4.3kHz±0.05kHz
Narrow
2) Menu No. : 90
 Transmit
2.2kHz±0.05kHz
24. HF SWR 
protection
1) Menu No. : 118
  (Frequency : 14.1MHz)
 Transmit
 150Ω dummy connection
    : Use a cable that is 1m long
Through 
type power 
meter
150Ω dummy
ANT2
[+] key
or
[–] key
Set the adjustment 
value within the 
limit of the specifi ed 
power.
40W±1W
25. SWR meter
  (SWR : 3)
1) Menu No. : 119
  (Frequency : 14.1MHz)
 Transmit
 150Ω dummy connection
    : Use a cable that is approx. 
      10cm long
[+] key 1 push
(SWR meter lights up to 3 
level.)
26. 50MHz
 SWR 
meter
  (SWR : 3)
1) Menu No. : 120
  (Frequency : 50.1MHz)
 Transmit
27. VHF SWR
 protection
1) Menu No. : 121
  (Frequency : 145.9MHz)
  ANT : Open
 Transmit
Ammeter
ANT144
[+] key
or
[–] key
Set the adjustment 
value within the limit 
of the specifi ed cur-
rent.
11A±0.25A
28. UHF SWR
 protection
1) Menu No. : 122
  (Frequency : 438.1MHz)
  ANT : Open
 Transmit
ANT430
9.25A±0.25A
• Writing data : After items 5~8 and 12~28 have been adjusted;
   1) Menu No. 124
   2) [+] or [–] key : Push once time. Display “rEAdy” → “good” (If “nG” is displayed, enter data again.)
   3) [CLR] key : Push once time.
29. AT detec-
tion balance
1) Display f. : 51.990MHz
  Mode : CW
  Power : 10W
 Transmit
Oscilloscope
Power 
meter
Filter
Rear
panel
TP1
(AMD)
ANT1
Filter
VR2
Turn the VR2 to the 
point where the 
waveform on the os-
cilloscope changes 
from high to low.
(Threshold point)
1200MHz Unit Transmitter Section
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
1. TX IF gain
1) Display f. : 1270.000MHz
  Mode : CW
  Carrier : 0
 Transmit
Spectrum 
analyzer
Power 
meter
Rear 
panel
ANT1.2G TX-RX3
Set the carrier level 
at approx. 100mW.
L2
L3
L9
Power max.