Kenmore 27'' Laundry Center w/ Gas Dryer Installation Guide

Page of 60
29
27” Models
60 Sq. In.
60 Sq. In.
12. Mobile or manufactured home installation
• Installation MUST conform to the MANUFACTURED HOME
CONSTRUCTION & SAFETY STANDARD, TITLE 24, PART
32-80 or, when such standard is not applicable, with
AMERICAN NATIONAL STANDARD FOR MOBILE HOME,
ANSI/NFPA NO. 501B.
• The appliance MUST be vented to the outdoors with the
termination securely fastened to the mobile home structure.
• The vent MUST NOT be terminated beneath a mobile or
manufactured home.
• The vent duct material MUST BE METAL.
• KIT 14-D346-33 MUST be used to attach the appliance se-
curely to the structure.
• The vent MUST NOT be connected to any other duct, vent,
or chimney.
• Do not use sheet metal screws or other fastening devices
which extend into the interior of the exhaust vent.
• Provide an opening with a free area of at least 25 sq. in for
introduction of outside air into the dryer room.
13. Alcove or closet installation
• If your appliance is approved for installation in an alcove or
closet, it will be stated on a label on the appliance back.
• The dryer MUST be vented to the outdoors. See the EXHAUST IN-
FORMATION section.
• Do not install this appliance with less than the minimum clear-
ances shown above.
• The closet should be vented to the outdoors to prevent gas pock-
eting in case of a gas leak in the supply line.
• No other fuel-burning appliance shall be installed in the same
closet with the appliance.
CONSIDERATION MUST BE GIVEN TO PROVIDE ADEQUATE
CLEARANCES FOR INSTALLATION AND SERVICE.
DOOR VENTILATION OPENING
When louvers or registers are placed in door openings, the
free air openings of the louvers or registers must equal 120
square inches.
A minimum of 120 square inches of opening, equally divided
at top and bottom, is required. Air openings are required to
be unobstructed when a door is installed. A louvered door
with equivalent air openings for the full length of the door is
acceptable.
14. Bathroom or bedroom installation
For replacement parts and other information, see the back
cover of this Use & Care Guide for service phone numbers.
15. Servicing
LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING CONTROLS. WIR-
ING ERRORS CAN CAUSE IMPROPER AND
DANGEROUS OPERATION AFTER SERVIC-
ING/INSTALLATION.
WARNING
• The appliance MUST be vented to the outdoors. See EX-
HAUST INFORMATION section 6 & 7.
• The installation must conform with local codes or, in the ab-
sence of local codes, with the NATIONAL ELECTRICAL
CODE, ANSI/NFPA NO. 70 and NATIONAL FUEL GAS
CODE, ANSI Z223.
DO NOT INSTALL THIS APPLIANCE IN A
CLOSET WITH A SOLID DOOR.
WARNING