Kentrox AI232 User Manual

Page of 322
AI232 Version 9.6x User’s Guide
AI232 Commands: pvclist
8-81
Second column
Displays the timer type for the PVC. Possible values are:
z
ct
—Displays the connect timer if the PVC is active. The 
number indicates the timer setting in seconds.
z
it
—Displays the inactivity timer if the PVC is a connect-on-
activity PVC. The number indicates the timer setting in 
seconds.
z
Passive
—Appears if the PVC is a passive type of PVC.
Third column
Defines the state of the PVC. Possible values are:
z
idle
—Indicates the PVC is ready to connect.
z
dataxfer
—Indicates the PVC is connected and able to pass 
data.
z
incon
—Indicates the PVC is in a transition state.
z
attaching
—Indicates the PVC is in a transition state.
z
not attached
—Indicates that the PVC is not connected.
z
detached
—Indicates the PVC is in a transition state.
If the display indicates one of the transition states, this should 
only appear for a short period of time. If the state remains in this 
condition, contact Technical Support.
Fourth column
Defines the MuxID, which is an internal number used by 
developers to describe which data stream is used for the 
connection.
Fifth column
Defines the file descriptor, which is an integer value used by 
developers to describe which data stream is used for the 
connection.
Sixth column
Defines the flag, which gives a code that indicates the purpose of 
the data stream.
Column
Description