Kentrox AI232 User Manual

Page of 322
AI232 Version 9.6x User’s Guide
AI232 Commands: staslc
8-93
Examples
This example displays the link and cable status information for links 
1
 to 
5
.

Note: Not all links are displayed here. Entering the command with no additional 
parameters would show all 32 links.
[232]staslc 1-5
Link   Status  Appl. DTR RTS CTS DSR DCD  Format     Parity Frame Overun Underun
  1:     Idle Login   +   +   -   -   -   9600,8,n,1     0     0      0       0
  2: Disabled Login   ?   ?   ?   ?   ?   9600,8,n,1     0     0      0       0
  3:   -MMUX          ?   ?   ?   ?   ?  19200           0     0      0       0
  4: Disabled Login   ?   ?   ?   ?   ?   9600,8,n,1     0     0      0       0
  5: Disabled Login   ?   ?   ?   ?   ?   9600,8,n,1     0     0      0       0
 DP232 Cable Status: Ports 1-8   Connected       Ports 9-16  Not Connected
                     Ports 17-24 Not Connected   Ports 25-32 Not Connected
[232]
Column
Description
Link
Displays the number of the link.
Status
Displays the link status as 
dataxfer
 (data is being transfered), 
idle
, or 
disabled
.
Appl.
Displays the application specified for the link (
Alias
Login
, or 
Destination
).
DTR RTS CTS DSR DCD
Displays the status of the control signals. (
+
 means the signal 
is asserted and 
-
 means the signal is negated.)
Format 
Displays the baud rate, number of data bits, parity (
none
odd
or 
even
), and number of stop bits specified for the link.
Parity
Displays the number of parity errors.
Frame
Displays the number of framing errors.
Overun
Displays the number of overrun errors.
Underun
Displays the number of underrun errors.