Jabra IEC 61036 User Manual

Page of 10
Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) 
Page 7                                      1/26/2005   Rev 1.0.01 
Appendix A:
 Warning and Error Information  
 
 
ERR   2 
Error Info 
 
 
0000 0001 
Clock ‘s Oscillator Error 
 
0000 0010 
Read/Write Clock Error 
 
0000 0100 
Read/Write EEPROM Error 
 
0000 1000 
Read /Write Cs5460A Error 
 
0001 0000 
CPU Program Error 
 0010 
0000 
reserved 
 
0100 0000 
Low  Battery Voltage 
 
1000 0000 
SPI Read or Write Error 
 
 
 
ERR   1 
Warning Info 
 
 
0000 0001 
Over Voltage 
 
0000 0010 
Under Voltage  
 
0000 0100 
Phase Voltage Loss  
 
0000 1000 
 Phase failure 
 
0001 0000 
Current Reversal 
 
0010 0000 
Energy Reversal  
 
0100 0000 
Missing Current  
 
1000 0000 
Phase Sequence Reversal 
 
 
 
 
AttentionEvery Event of Warning or Error Use One Numberif  Missing Voltage 
and Over Voltage
Display ”0000 0101”