Multiplex Technology 16CH User Manual

Page of 60
20
▲▼
◄►
: navigates between targets.
d)
LS :
The sensitivity of comparing two different images. The smaller the value is, 
the higher sensitivity for motion detection. 
The highest sensitivity setting is 00,  the lowest sensitivity setting is 15. The 
default value is 07. 
e)
SS :
The sensitivity towards the size of the triggered object on the screen.(the 
number of motion detection grids). The smaller the value is, the higher 
sensitivity for motion detection. 
The highest sensitivity setting is 00, and the lowest sensitivity setting is 15. 
The default setting is 03.
Note:  The default setting of Spatial Sensitivity is 03, which means when 3 grids 
are detected for motion at one time, the system will get triggered. So the 
value of Spatial Sensitivity must be less than the number of grids which you 
set up to motion detection area.
f)
TS :
The sensitivity towards how long the object gets triggered. The smaller the 
value is, the higher sensitivity for motion detection.
The highest sensitivity setting is 00, and the lowest sensitivity setting is 15.  
The default setting is 02. 
g)
RE :
The value of RE is a reference for detection. The default value is 10, which 
means DVR will compare 10 continuous images at one time according to 
the sensitivity of LS, SS, TS simultaneously. Therefore the bigger the value 
is, the higher sensitivity for motion detection.
h)
ALARM:
Select LOW / HIGH for the alarm polarity. The default alarm value is OFF. 
i)
PRE / NEXT:
Select “PRE” to go to the previous page; Select “NEXT” to go the next 
page. Targets set in the AREA.
DETECTION TIMER
DETECTION TIMER
DATE
START
END
OFF
00  :  00    -
00  :  00
DAILY
08  :  00    -
18  :  00
SUN
06  :  00    -
23  :  00
MON-FRI
00  :  00    -
00  :  00
OFF
00  :  00    -
00  :  00
OFF
00  :  00    -
00  :  00
OFF
00  :  00    -
00  :  00
2)
DETECTION TIMER:
Set the date, start time, end time of the detection function.