MSC COM EXPRESS CX-MB-EVA2 User Manual

Page of 46
CX-MB-EVA2 
 User's Manual 
 
 
Hardware  
41 
4.22 
OnBoard BIOS-Flash 
There is a PLCC32 socket on the mother board, where an additional firmware hub can 
be inserted. To boot from this firmware hub, the firmware hub on the COM Express 
module has to be disabled with J0203.  
 
 
4.23 
POST-Code Display 
For debugging purposes a POST code display is implemented on the base board, thus 
enabling the display of BIOS outputs on IO-port 80h and/or Port 90h. 
In addition, these signals are output on a pin header. For protocolling purposes a logic 
analyser can be connected here. 
The pinout of the output connector X44 corresponds to the pinout of the Hewlett Packard 
HP-PODs. 
 
Specification: 
  References:  
X44 
  Connector: 
20-pin header 2.54mm 
Pinout: 
Refer to Table 29 
Pin 
HP-POD 
Function 
Pin 
HP-POD 
Function 
+5V 
not used 
CLK2 
LPC_CLK 
CLK1 
not used 
D15 
not used 
D14 
not used 
D13 
Test signal 3 
D12 
Test signal 2 
D11 
Test signal 1 
D10 
Test signal 0 
10 
D9 
not used 
11 
D8 
Strobe 
12 
D7 
Data 7 
13 
D6 
Data 6 
14 
D5 
Data 5 
15 
D4 
Data 4 
16 
D3 
Data 3 
17 
D2 
Data 2 
18 
D1 
Data 1 
19 
D0 
Data 0 
20 
GND 
Ground 
Table 29   Pinout POST Display (HP-POD) 
 
 
4.23.1  Lattice Programming Interface 
 
A connector used to program the PLD to decode the POST codes is implemented. To 
reprogram the PLD a Lattice programming adapter is required. 
 
Specification: 
  References:  
X47 
  Connector: 
CAB 714-91-164-31-007 (socket) 
  Pinout:  Refer to Table 30