MiTAC 8170 User Manual

Page of 217
172
8170 N/B MAINTENANCE
IEEE1394 Test Error
1. Check if the  1394 device  is installed 
properly.
2. Confirm 1394 driver is installed ok. 
Test
OK?
Re-test
OK?
Yes
No
Yes
No
Change the faulty 
part then end.
Try another known good
1394 device.
Correct it
Replace
Motherboard
Check the following parts for cold solder or one of the following 
parts on the mother-board may be defective, use an oscilloscope
to check the following signal or replace the parts one at a time and 
test after each replacement.
Parts:
Signals
PCI BUS SIGNAL
PCICLK_CARD
-CBE[0:3]  -IRQ0
-GNT0  -CARD_RI
SERIRQ  -INTA
-INTC    CBRST
VCCEN0  VCCEN1
PHY_D[0:7]
PHY_CTL[0:1]
PHY_LREQ
PHY_CLK
PHY_LKON
PHY_LPS
TPA+
TPA-
TPB+
TPB-
PHY_XI
PHY_XO
U507  
U17      U7 
U8           U14       X504
C134       C152      Q5
Q4           R43        R42 
R53         R52    
U9
C99         L23      L24
J21          R105      R103
R115       R106      R124
C199      C200 
R607
Board-level
Troubleshooting
8.13 IEEE1394 Failure
An error occurs when a PC card device or 1394 device is installed.