Mitsubishi Electronics J2-JRSERIES MR-J2-03A5 User Manual

Page of 185
7 -  3
7. ADJUSTMENT
7.2 Gain Adjustment
7.2.1
Parameters required for gain adjustment
Parameter No.
Symbol
Name
No. 2
ATU
Auto tuning
No. 6
PG1
Position loop gain 1
No. 22
*OP4
Function selection 4 (machine resonance filter)
No. 34
GD2
Ratio of load inertia moment to motor inertia moment
No. 35
PG2
Position loop gain 2
No. 36
VG1
Speed loop gain 1
No. 37
VG2
Speed loop gain 2
No. 38
VIC
Speed integral compensation
7.2.2
Block diagram
OP4
Machine
resonance
suppression filter
PG1
VG1
PG2
+
VG2
VIC
J
M
ENC
L
J
M
ENC
Actual loop
section
Command
Virtual motor
Virtual encoder
Machine
Motor
Encoder
Model 
section
+
+
+
+
Auto tuning
section
The block diagram of the Servo Amplifier servo control section is shown above. (The current loop is
omitted.)
(1) Actual loop section
A control loop designed to control the actual motor and acts to control the servo system stably in
response to the load torque of the machine.
(2) Model section
Acts to provide the ideal operation values to the current loop in response to the command.
(3) Auto tuning section
Judges the load inertia moment of the machine fitted with the actual motor from the operation error of
the motor to change each control gain in real time.
The gains changed by auto tuning are PG1, VG1, PG2, VG2 and VIC.