Mitsubishi Electronics J2-JRSERIES MR-J2-03A5 User Manual

Page of 185
3 -  46
3. SIGNALS AND WIRING
(2) Fitting of earth (E) terminal (AERSBAN-JR)
As shown below, fit the earth (E) terminal to the bottom or top of the servo amplifier.
Positioning boss
Earth (E) terminal
AERSBAN-JR
M4 screw
3.10 Instructions for the 3M Connector
When fabricating an encoder cable or the like, securely connect the shielded external conductor of the cable
to the ground plate as shown in this section and fix it to the connector shell.
External conductor
Sheath
External conductor
Pull back the external conductor to cover the sheath
Sheath
Core
Strip the sheath.
Screw
Screw
Ground plate
Cable