Pressure Systems, Inc.                                                                                        Model 9116 User’s Manual 
 
 
 
Page 5 
 
www.PressureSystems.com 
Additional enhancements to the Model 9116 
 
Software Scan List Speeds:  
Software Scan lists can be run as fast as hardware trigger scan lists on the 
Model 9116 (~500 Hz. See specification sheet).  The Model 9016 was 
limited to 100 Hz maximum software trigger scan lists. 
 
Firmware Updates/Boot Loader
The firmware in the Model 9116 may be updated in situ, over its Ethernet 
connection. This is the preferred method for updating the firmware and may 
be invoked at any time.  (See Section 5.2.1).  
 
The user must connect to the updated module.  Establishing a TCP/IP 
connection is the last step in validating a successful firmware update. If the 
unit is power-cycled four times without establishing a TCP/IP connection, the 
firmware update will be tagged as invalid. The Model 9116 contains a 
protected resident boot loader that will then take over operation of the 
module.  The resident boot loader resides in protected memory.  It monitors 
the state of the firmware and the operation of any downloads.  Even in the 
event of a power failure during a firmware update, upon return of power, the 
resident boot loader will be available, and will establish communications for 
downloading new firmware.  The user can determine that the Model 9116 is 
in boot loader mode by observing that the firmware version reported by the 
module is less than 1.0   In boot loader mode, the Model 9116 will return an 
‘N08’ in response to the ‘a’, ‘c’, ‘m’, ‘n’, ‘r’, and ‘t’ commands. 
 
 
1.3  
Options 
 
1.3.1  
Pressure Ranges 
 
Model 9116 contains sixteen (16) DH200 transducers. These transducers are available with full 
scale pressure ranges from 10" H
2
O (inches of water column) to 750 psid (2.5 kPa  to  5200 
kPa).  Transducers with different pressure ranges may be combined in a single module. 
 
Please consult the Sales Department at Pressure Systems for availability of other pressure 
ranges   (1-800-678-SCAN (7226)). 
 
1.3.2  
  Manifolds and Pressure Connections 
 
Model 9116 sixteen-channel Intelligent Pressure Scanners are available with a true differential 
or common reference pneumatic manifold, and have a standard purge and leak check manifold. 
They are available with standard 1/8" or optional 1/16" and 1/4" compression fittings.  All fittings 
utilize an SAE 5/16 - 24 O-ring boss which supports a variety of other adapter compression 
fittings.  They are also available with a quick disconnect plate which contains 0.063" bulge 
tubulation.  The common differential version is available with all choices of fittings.  The true 
differential version is available with 0.063" bulged tubulation fittings only. 
 
Consult the Sales Department at Pressure Systems at 1-800-678-SCAN (7226) for availability of 
other input fittings.