Measurement Specialties 9116 User Manual

Page of 143
Pressure Systems, Inc.                                                                                        Model 9116 User’s Manual 
 
 
 
Page 60 
 
www.PressureSystems.com 
Example: 
● 
 
Configure stream l to return temperature status field, and all Pressure EU data 
 
“c 05 1 0012” 
 
  Read 
response: 
 
 
 
“A” 
 
 
 
If or when stream 1 is subsequently enabled, data groups in that stream with the  
 
 
lowest-bit-numbers (table positions) selected are delivered first.  In this example  
 
 
(bbbb = 0012), the DH Temperature Status datum would be first, and then all  
  the 
specified 
Pressure EU data would follow (highest specified channel to lowest  
 
 
specified channel).  The standard 5-byte binary prefix (tssss) that begins all  
 
 
stream packets would precede this status and data group.(See the Autonomous  
  Packet 
box 
in 
Start Stream sub-command (index 01.)