Pressure Systems, Inc.                                                                                        Model 9116 User’s Manual 
 
 
 
Page 70 
 
www.PressureSystems.com 
 
06 
IP Address Resolution Method, as hex state: (default = 0000) 
 0000 
Use Static IP Address stored in module’s non-volatile 
memory 
 0001 
Get Dynamic IP Address from external RARP/BOOTP 
server 
13 
07 
Host Response/Stream Back-Off Delay, as hex value (or FFFF).  FFFF 
means use low-order byte of module’s Ethernet Address as value 
instead.  In either case, back-off delay in microseconds is calculated from 
decimal equivalent of hex value:  
delay = decvalue * 20 
14 
08 
Host Response/Stream Total Size Prefix (with 2-byte big-endian binary 
value), added to all command responses and streams to indicate their 
true length in bytes:  
 
0000 = None (default) 
 
0001 = Yes 
16 
09 
TCP Connect Port, as hex value (e.g. 2328 = 9000 decimal, default). 
17 
0A 
Auto UDP Broadcast@Reset, as hex state: 
 
0000 = No (default) 
 
0001 = Yes 
18 
0C 
Temperature Status of Each Scanner Transducer, as 16-bit hex bit 
map, each bit representing the current status of a transducer/channel 
(16-1)). Bit values are: 
 
0= transducer operating within the specified operational limits. 
 
1= transducer operating outside the specified limits. 
(see end-of-table NOTE +) 
 
0D 
Minimum Temperature Alarm Set Point (in degrees C), as decimal (**) 
format 0  representation of internal IEEE float, with leading space). 
19 
0E 
Maximum Temperature Alarm Set Point (in degrees C), as decimal (**) 
format 0  representation of internal IEEE float, with leading space). 
19 
11 
Thermal Update Scan Interval (in seconds) as decimal (**) integer 
value. 
1B 
31 
Module hardware version number in the form e.eeeeee.  (9016 returns 
‘N08’ 
 
32 
Hardware trigger mode. 
   0=positive 
going 
edge 
   1=negative 
going 
edge 
   2=trigger 
on 
any 
edge 
   (9016 
returns 
‘N08’) 
32 
3c 
Temperature Range, as a hex value 
0000 = range 0 to 60ºC (default) 
0006 = range -30 to 60º C 
0007 = range -20 to 70ºC 
 
 
(+) NOTE
This 4-byte hex status fields may also be returned in autonomous data streams, but as  
 
 
pure binary extensions of each stream’s packet binary header (see ‘c’ command, ii=05,  
 
 
bbbb=0002).