Matsushita MPE-33R User Manual

Page of 20
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
3
Figure 1
TOOLS AND BUILDING SUPPLIES
NORMALLY REQUIRED
Tools:
 Phillips 
Screwdriver
 
7/16" Socket Drive
 Hammer
 
Saw And/or Saber Saw
 Level
 Measuring 
Tape
 Plumb 
Line
 
Electric Drill And Bits
 Pliers
 Square
 Gloves
Building Supplies:
 Framing 
Materials
 
Wall Finishing Materials
 Caulking 
Materials 
  
(noncombustible)
IMPORTANT NOTE: This fi replace system 
is not diffi cult to install. However, in the 
interest of safety, it is recommended that 
the installer be a qualifi ed or certifi ed 
“tradesman” familiar with commonly 
accepted fi replace installation and safety 
techniques as well as prevailing local 
codes.
LOCATING YOUR MERIT PLUS ELECTRIC 
FIREPLACE
Your new fi replace may be installed into existing 
framing or built into a wall (see Figure 1), or 
set in a freestanding mantel cabinet available 
from your dealer (see Page 17).
When choosing a location for your new fi re-
place, ensure that the general instructions are 
followed.  Also, for the best effect, install the 
fi replace out of direct sunlight and away from 
overhead lighting.  See Figure 1.
Top View Showing Approved 
Room Locations of Fireplace
fi replace shown in gray.
GENERAL INFORMATION
Power Supply Wire Specifi cations
120 Volt, 60 Hz, 1600 Watts:
(ref. Page 10)
Use two conductor, non-metallic sheath cable 
with ground wire for the incoming power 
supply.  The wire used must conform to local 
and national electrical codes for the specifi ed 
power consumption rating. See Table 1.
240 Volt, 60 Hz, 3000 Watt:
(ref. Page 11)
Use three conductor, non-metallic sheath 
cable with ground wire for the incoming power 
supply. The wire used must conform to local 
and national electrical codes for the specifi ed 
power consumption rating. See Table 1.
Wall Switch or Wall Thermostat Kits
(optional kits, see Page 17)
Low voltage wire is provided for the wall switch 
connection.  The wires gage requirements are 
shown on Table 1.
DO NOT USE THIS APPLIANCE OUT-
DOORS. DO NOT EXPOSE FIREPLACE TO 
THE ELEMENTS (SUCH AS RAIN, ETC.).
THIS APPLIANCE IS NOT INTENDED FOR 
USE IN BATHROOMS, LAUNDRY AREAS 
OR SIMILAR INDOOR LOCATIONS.  NEVER 
LOCATE THIS APPLIANCE WHERE IT 
COULD FALL INTO A BATHTUB OR OTHER 
WATER CONTAINER.
DO NOT RUN ELECTRICAL WIRING OR 
POWER CORD (OPTIONAL) UNDER CAR-
PETING. OR COVER WITH THROW RUGS, 
RUNNERS OR SIMILAR MATERIALS.  
(FOR 120 V W/OPTIONAL POWER CORD)  
AVOID THE USE OF AN EXTENSION CORD 
BECAUSE THE EXTENSION CORD MAY 
OVERHEAT AND CAUSE A RISK OF FIRE.  
HOWEVER, IF YOU HAVE TO USE AN 
EXTENSION CORD, THE CORD SHALL BE 
NO. 14 AWG MINIMUM SIZE AND RATED 
NOT LESS THAN 1800 WATTS, 15 AMPS.  
THE EXTENSION CORD MUST BE A THREE 
WIRE CORD WITH GROUNDING TYPE 
PLUG AND CORD CONNECTION.
THIS APPLIANCE HAS HOT AND ARCING 
OR SPARKING PARTS INSIDE.  DO NOT 
USE IT IN AREAS WHERE GASOLINE, 
PAINT OR FLAMMABLE LIQUIDS ARE 
USED OR STORED.  
THIS FIREPLACE SHOULD NOT BE USED 
AS A DRYING RACK FOR CLOTHING, 
NOR SHOULD CHRISTMAS STOCKINGS 
OR OTHER DECORATIONS BE HUNG 
NEAR IT.
USE THIS APPLIANCE ONLY AS DESCRIBED 
IN THIS MANUAL.  ANY OTHER USE IS NOT 
RECOMMENDED BY THE MANUFACTURER 
AND MAY CAUSE A FIRE, ELECTRIC SHOCK 
OR INJURY TO PERSONS.
IF APPLIANCE IS TO BE DISCONNECTED, 
TURN OFF CONTROLS FIRST.
DO NOT INSERT OR ALLOW FOREIGN 
OBJECTS TO ENTER ANY VENTILATION 
OR EXHAUST OPENING, AS THIS MAY 
CAUSE AN ELECTRIC SHOCK, FIRE, OR 
DAMAGE TO THE APPLIANCE.
SAVE THESE INSTRUCTIONS.
       WARNING 
Do not install or operate this fi re-
place through a switch wired in the 
120 V AC or  240 V AC circuits.  The 
only approved wiring for a switch 
is through the low voltage circuit  
(24 V AC) as shown on Page 14
.
Table 1
Power Supply Wire Gage 
Voltage
Wire Gage
Fuse 
Rating
120 V
14 GA.
15 AMP
240 V
14 GA.
20 AMP
Wall Switch / Thermostat Wire Gage
Voltage
Wire Gage
5 VOLTS
18 GAGE