NOTICE:  A qualifi ed gas appliance installer must connect the heater to the gas supply. Consult all 
local codes.
IMPORTANT: Loosen the pipe adapter on the fl ex tube before installing to the system piping.
Figure 17 - Gas Connection 
To Heater 
Valve
Stainless
Flexible Tube
CONNECTING THE GAS
Use new black or steel pipe. Internally tinned copper or copper tubing can be used 
per National Fuel Code, section 2.6.3, providing gas meets hydrogen sulfi de limits, 
and where permitted by local codes. Gas piping system must be sized to provide 
minimum inlet pressure (listed on Data Plate) at the maximum  fl ow rate (BTU/Hr). 
Undue pressure loss will occur if the pipe is too small.
A manual shutoff valve must be installed upstream of the appliance. Union tee 
and plugged 
1
/
8
" NPT pressure tapping point should be installed upstream of the 
appliance. See Figure 17.
CAUTION
Manual Shutoff
Valve
Pipe
Pipe  Coupling    
Always use an external regulator for all propane/L.P.G. heaters and high pressure one to two-pound systems only, to 
reduce the supply tank pressure to a maximum of 13" w.c.  This is in addition to the internal regulator in the heater valve. 
CHECK GAS TYPE: The gas supply must be the same as stated on the heater's rating 
plate.  If the gas supply is different, DO NOT INSTALL THE HEATER.  Contact your 
dealer for the correct mode.
W
ARNING
Locations that Pressure 
Tapping Point May Be 
Installed 
Gas Supply 
Inlet