MartinLogan VENT-FREE FIREPLACE SYSTEMS 33ISDG User Manual

Page of 40
23D8036 
29
OPERATING INSTRUCTIONS
  1.  STOP! Read the safety information label.
  2.  Make sure the manual shutoff valve is fully open.
  3.  This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo 
ignitor does not light the pilot, refer to instructions for “Match Lighting Instructions,” page 30.
  4.  Turn gas control knob clockwise 
 to the OFF position and turn ON/OFF switch to OFF position.
  5.  Wait (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! 
Follow "B" in the safety information label. If you don't smell gas, go to next step.
  6.  From OFF position, turn the gas control knob counterclockwise 
 to IGN position. Push in control 
knob for 5 seconds. NOTE: If you are running the heater for the fi rst time, it will be necessary 
to press in the control knob for 30 seconds to allow air to bleed out of the gas piping. 
  7.  With the control knob pushed in, push in and release the piezo ignitor button to light the pilot.
  8.  Continue pushing the control knob in for a further 60 seconds to prevent the flame detector from 
shutting off the gas while the probe is warming up. Release the control knob.
  9.  Turn gas control knob counterclockwise 
 to the ON position.
 10.  After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch to ON 
position or adjust thermostat to desired setting.
 11.  If the gas logs will not operate, follow the instructions “To Turn Off Gas To Appliance” below and call 
your service technician or gas supplier.
Figure 35 - Pilot 
Figure 36 - Control Cover Plate for Milli-Volt 
Hi/Lo Control 
Ignitor Pilot Control
On/Off Switch
Piezo
 
TO TURN OFF GAS TO HEATER
 
  1.  Turn control knob clockwise 
 to OFF position to completely shut off the heater.
  2.  If applicable: Turn ON/OFF switch to OFF position and/or set thermostat (if present) to lowest setting.
  3.  If applicable: Turn off all electric power to the heater.
MILLI-VOLT/THERMOSTAT CONTROL 
LIGHTING INSTRUCTIONS