Maretron TLM150 User Manual

Page of 21
 
 
 
 
 
Revision 1.2 
 
Page 15 
®
®
Mechanical 
Parameter 
Value 
Comment 
Size 
3.9”” x 1.2” x 1.0”  
(99mm x 30.5mm x 
25.4mm) 
Interface Component 
 
2.7” dia. X 0.9”  
(68.6mm dia. x 22.9mm) 
Sensor Component 
 
8.5” (215.9mm) 
Interconnecting Cable 
Weight 
12 oz. (340g) 
 
Mounting 
SAE J1810 5-hole bolt 
pattern 
Can mount to 1.25” BSP or 1.5” NPT using 
available adapters 
 
Environmental 
Parameter 
Value 
IEC 60945 Classification 
Exposed 
Degree of Protection 
IP67 
Operating Temperature 
-25°C to 55°C 
Storage Temperature 
-40°C to 70°C 
Relative Humidity 
93%RH @40° per IEC60945-8.2 
Vibration 
2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s
2
 per IEC 60945-8.7 
Rain and Spray 
12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8 
Solar Radiation 
Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10 
Corrosion (Salt Mist) 
4 times 7days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12 
Electromagnetic Emission 
Conducted and Radiated Emission per IEC 60945-9 
Electromagnetic Immunity 
Conducted, Radiated, Supply, and ESD per IEC 60945-10 
Safety Precautions 
Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12 
 
 
 
 