Lynx D AD 3220 B User Manual

Page of 25
Reference Manual D AD 3220 B Version 1.0
 
 
Page 19  
 
 
Locate Function 
For larger systems which may have multiple 
MiniModules of the same type in a single rack, or 
multiple rack systems on a large central control 
system we have added a useful utility which will 
help to visually locate a suspect module quickly 
(When used in conjunction with the optional 
control system and software) 
 
Once the specific module has been selected on 
the control system there is a locate button on the 
top of the GUI: 
 
 
 
 
 
 
 
 
                       Locate Function in Control System 
 
When Locate is selected the status indicator on the 
GUI and the module LED`s will flash yellow in the 
following continuous sequence.  
 
3 short flashes…. Pause…. 3 short flashes … 
 
This uses the alarm LED located on the front of the 
module and in some cases any channel or status 
LED`s that may be used in the module. 
 
Use of the locate function will not interfere with the 
normal operation of the module. 
 
For more details on this feature please check the 
documentation supplied with the controller 
software.