Extend Connection 
 
Bus Extension. This connection is used to interface 
racks together when using the optional LYNX 
control system. This is a simple (and inexpensive) 
way to extend the reach of the host RCT 5020 
controller into several more racks fitted with RCT 
5010 bus expanders. It uses a proprietary LYNX 
control interface and this connection is physically 
daisy chained between all connected racks. 
Connection details can be seen in the table below. 
 
The connection is a 9 pin SubD female connector. 
Function and connection information is described 
below.  
 
Connector wiring detail when used for the Bus 
Extension 
 
 
 
 
 
 
 
Note the “prop” term refers to proprietary for the 
LYNX interface. 
 
 
 
 
 
 
 
                                   Figure 7. Extend Connector 
 
Note. When using this interface all connected racks 
must be mounted close together, (preferably with 
no space in-between racks), as the distance of this 
interface is restricted. Please refer to the R CT 5010 
Rack Bus Expander reference manual for more 
details on this interface and the cables required. 
Pin 
Number 
Connection 
Pin 
Number 
Connection 
 1 
Prop CLK A 
Prop CLK B 
Prop TX A 
Prop TX B 
Prop RX B 
Prop RX A 
4 GND 
9  Prop 
SEL 
Prop SEL 1 
 
 
1
5
6
9