Lynx Computer Accessories R FR 5010 User Manual

Page of 39
Reference Manual R FR 5010 Version1.4
 
 
Page 35  
 
 
Specifications
 
(R FR 5010 / R FR 5011)
 
Mechanical 
 
Size 
2 RU high x 32.5 cm deep including connectors 
and front cover. 31 cm without front cover. 
Standard 19” rack mount. 
Weight (empty) 
R FR 5010: 4 kg with single power supply 
R FR 5011: 4,25 kg with single power supply 
Connections 
All connections made on rear of rack 
 
 
Performance
 
Available Card Slots 
10 x CardModules 
 1 
Controller 
 
2 x Power Supplies (primary and redundant) 
Power Indication (alarm) 
One multifunction LED per supply and GPO output
 
Fan Alarm through front cover (R FR 5011 only) 
 
Module alarm LEDs visible through front cover 
Controller alarm 
LED bar  
 
Connections 
(rear connections) 
LAN Connector 
RJ 48 
Control 
9 Pin female SubD (RS 485) 
Extend 
9 pin female SubD (RS 232) 
Alarm Connector 
9 Pin male Sub D (GPO and GPI) 
Ref In 
BNC connection for rack reference, with loop 
output 
Primary AC 
IEC power connector, fused (2A) 
Redundant AC 
IEC Power connector, fused (2A) 
 
Electrical Specifications
 
Power Input 
100 – 240VAC, 50Hz – 60Hz. Two separate and 
isolated connections for Primary and Redundant 
supplies. 
Power Consumption 
130W max. 
Safety 
IEC 60950/ EN 60950/VDE 0805 
 
Ambient
 
Temperature 
5°C to 40°C Maintaining specifications 
0°C to +50°C Operating 
Humidity 
Max 90% non condensing 
 
Supplied Accessories
 
Documentation 
R FR 5010 / R FR 5011 Reference Manual