Authorization codes 
20
NOTE:
To maintain system security, Lucent recommends you use 
authorization codes.
Authorization codes may be used to:
Override a facility restriction level (FRL) assigned to an originating station 
or trunk
Restrict individual incoming tie trunks and remote-access trunks
Track Call Detail Recording calls for cost-allocation purposes
Provide additional security control
You can make authorization codes mandatory by setting, on the trunk group 
screen, the Auth Code field to 
y
. Refer to 
‘‘Trunk Group’’ on page 967
 for more 
information.
More information
When you dial an authorization code, the FRL assigned to the extension number, 
attendant console, incoming trunk group, or remote access trunk group being used 
for the call is replaced by the FRL assigned to the authorization code. The new 
FRL functions the same as the one it replaces; however, the new FRL may 
represent greater or lesser calling privileges than the FRL that it replaces. Access 
to any given facility depends on the restrictions associated with the authorization 
code FRL.
Example
A supervisor is at a desk of an employee and wants to make a call that is not 
normally allowed by the FRL assigned to that employee’s extension. The 
supervisor, however, can still make the call by dialing an authorization code that is 
assigned an FRL that is not restricted from making that type of call.
For security reasons, authorization codes range from 4 to 13 digits. The number of 
digits in the codes must be a fixed length for a particular DEFINITY ECS.
NOTE:
Once established, the number of digits (4 to 13) in the authorization 
code remains fixed unless all codes are removed and re-entered. All 
authorization codes used in the system must be the same length.
Incoming trunk groups within a system may be administered to always require an 
authorization code. The system applies recall dial tone to a call when the user 
must dial an authorization code. If the user dials a correct authorization code 
within 10 seconds (interdigit timeout), the call completes as dialed. If the user