Lucent Technologies Definity Enterprise Communication Server 8.2 User Manual

Page of 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Routing outgoing calls 
182
Setting up multiple locations 
8
2. Use the arrow keys to move to a blank Dialed String field.
3. Enter 
411
 in the Dialed String field.
4. Enter 
in the Total Mn and 
in Total Mx fields.
5. Enter 
1
 in the Route Pattern field.
6. Enter 
svcl
 (service call) in the Call Type field.
7. Press 
ENTER
 to save your changes.
Setting up multiple locations
When you define location numbers for the cabinets in a switch, you can create 
numbering plans and time zone and daylight savings plans that are specific for 
each cabinet. Choose the location you want to use as your main location, and 
offset the system clock time on each cabinet according to their its location.
Before you start
Be sure the Multiple Locations field on the System-Parameters Customer-Options 
screen is set to 
y
. If this field is set to n, contact your Lucent representative for 
more information.
Be sure your daylight savings rules are administered. Daylight Savings Rule 
numbers are located on the Daylight Savings Rule Screen 
Each cabinet in a switch and each port network in the cabinet must be assigned a 
location number. Refer to the maintenance information for your switch for more 
information. 
Instructions
For example, let’s set up multiple locations for a switch with cabinets in Chicago 
and New York. Location 1 is assigned to the cabinet in Chicago, our main office, 
so Central Standard Time is used for our main location. Location 2 is assigned to 
ARS DIGIT ANALYSIS TABLE
Location:  all
Percent Full:    6
Dialed 
Total 
Route  Call Node ANI
 String 
Min Max 
Pattern Type  Num 
Req
411__________________3_
3  ___ 1 
svcl
___ 
n
5____________________7 _ 7 ____ 2 
hnpa
___ 
n
6____________________7 _ 7 ____ 2 
hnpa
___ 
n
7____________________7 _ 7 ____ 2 
hnpa
___ 
n
911__________________3 3 ____ 1 
svcl
___ n